va-Q-Tcon³

General Information

  • Development in partnership with F. Hoffmann-La Roche Ltd. / Switzerland
  • Worldwide clinical trial supply, especially for temperatures from +2 °C to +8 °C
  • Officially validated for very strict summer and winter profiles
  • Year round packaging manual and easy set up (fail safe)
  • Single-use and multi-use boxes
  • Structure: EPP box, 6 pcs VIPs and 6 pcs va-Q-accus

Dimensions and weight


  • va-Q-Tcon³ 8 (single-use)
    - Article No.: BC000024
    - Exterior: 390 mm x 390 mm x 445 mm (h)
    - Interior: 200 mm x 200 mm x 200 mm (h)
      (product volume)
    - Total weight without payload: 11 kg

  • va-Q-Tcon³ 24 (single-use)
    - Article No.: BC000026
    - Exterior: 600 mm x 500 mm x 445 mm (h)
    - Interior: 410 mm x 310 mm x 210 mm (h)
      (product volume)
    - Total weight without payload: 20 kg

     

  • va-Q-Tcon³ 12 (multi-use)
    - Article No.: BC000102
    - Exterior: 500 mm x 400 mm x 445 mm (h)
    - Interior: 310 mm x 210 mm x 210 mm (h)
      (product volume)
    - Total weight without payload: 17.5 kg

  • va-Q-Tcon³ 12 (single-use)
    - Article No.: BC000025
    - Exterior: 500 mm x 400 mm x 445 mm (h)
    - Interior: 310 mm x 210 mm x 210 mm (h)
      (product volume)
    - Total weight without payload: 14 kg

  • va-Q-Tcon³ 24 longlife (multi-use)
    - Article No.: BC000027
    - Exterior: 600 mm x 500 mm x 445 mm (h)
    - Interior: 410 mm x 310 mm x 210 mm (h)
      (product volume)
    - Total weight without payload: 27 kg

Options

  • va-Q-accus on demand for different temperature ranges: -21 °C and +15 °C to +25 °C

Application

  • Especially developed for clinical trial shipments and goods, which need strict temperature control

Performance example for va-Q-Tcon³ Longlife

  • External temperature range: +20 °C ... +40 °C (Average +30 °C)
  • Internal temperature range: +2 °C ... +8 °C
  • Contents: 6 pcs precooled va-Q-accus
  • Performance: more than 3 days autonomy within a +2 °C ... +8 °C range

PER_E-MAIL_EMPFEHLEN

Kelvinhours EN final3

Do you know your packaging solution’s actual performance?

 

Bring light into the dark - with Kelvinhours. They combine necessary transportation time with required temperature rates – and simplify a direct comparison between different transport packaging options. Especially when transporting temperature-sensitive products making a good choice becomes a piece of cake.  

 
va-Q-tec’s Kelvinhours-calculator provides:
  • More certainty choosing the right packaging
  • Reduced risk on transport routes
Call to action final2en