• Deutsch (de)
  • Englisch (en)

va-Q-vip B

Characteristics

va-Q-vip B is a vacuum insulation panel for construction applications. va-Q-vip B is coverd with a high barrier film and an additional black glass fiber textile for mechanical shock protection. The core itself is non-combustible (Fire class A1). The va-Q-vip B with black glass fabric is inflammable (Construction materials class DIN 4102-B2). 

The va-Q-vip B is approved for general construction purposes in accordance with the approval number Z-23.11-1658, of the “Deutsches Institut für Bautechnik (DIBT)”. By 29th June 2011 the validity of the approval was extended until 30th June 2015.

va-Q-vip B elements stand out because of their smooth edges and corners due to special "edge fold technique va-Q-seam" individual elements can therefore be joined almost seamlessly.

Applications

va-Q-vip B can be used in buildings in accordance with application areas interior applications for ceilings, walls, floors, flat roofs, top floor ceilings, exterior insulation behind paneling, insulation in wood frame construction to the standard DIN 4108-10, Table 1.

Planners, installation partners or architects are responsible for the relevant specific insulation system. Application systems for buildings can also be discussed directly with va-Q-tec.

Advantage

  • Official approval for building material with assigned thermal conductivity 0.007 W/mK
  • Significantly reduced heat flows and thickness
  • Saves space providing more larger usable room area 
  • Extra protective layer for reliable installation

Product data

Surface colorBlack
GeometryRectangular shape without flanges*
Density (bulk, DIN EN 1602)180 - 210 kg/m³
Thermal conductivity
• Initial value< 0.0043 W/(mK) at 20 mm thickness (measured value)
• Rated value incl. aging & edge losses0.0070 W/(mK) by more than 20 mm thickness, 0.0080 W/(mk) at 10-15 mm thickness (measured value)
• If aerated0.020 W/(mK)
Temperature stability-70 °C to +70 °C
Thermal shock resistanceInsensitive to heat & cold shock in the given temperature range
Humidity stability0 % to 60 %
Internal gas pressure< 5 mbar (at delivery)
Increase of gas pressureapprox. 1 mbar/year (measured, 20 mm thickness)
Standard dimension (L x W) I & III: 1000 mm x 600 mm, II: 500 mm x 600 mm
Nonstandard dimension III & IVIII: Aera > 0,10 m² and < 0,60 m², IV: aera < 0,10 m²
Special designtriangle, trapezoud, corner cut, recessed surfaceand, panel with hole, flanges folding by 10 mm / 15 mm thickness
Thickness10 to 50 mm
Size tolerance
• 0 to 500 mm+2 / -4 mm
• 501 to 1000 mm+2 / -5 mm
Thickness tolerance± 1 mm
Specific heat0.8 kJ/(kg·K) (at room temperature)
U-value (with 20 mm thickness)
• Initial value0.22 W/(m²K) at 20 mm thickness
• Rated value incl. aging & edge losses0.35 W/(m²K) (measured value) at 20 mm thickness
Mass per area4 kg/m² (at 20 mm thickness)
Compressive strengthapprox. 150 kPa (at 10% compression)
FlammabilityDIN 4102-B2
Service lifeextrapolated, depending on application up to 60 years

* For 10 mm and 15 mm thicknesses, if a flat edge is required, the flanges are refolded onto the main surface of panel.

All figures are intended as a guide and should not be used for preparing specifications.