va-Q-tainer EURO
General information | |
The va-Q-tainer EURO has loading area for one EURO pallet inside (120 cm x 80 cm). The va-Q-tainer is extraordinarily suitable for the transportation of temperature sensitive goods, in particular pharmaceutical and biotechnological goods. The typical performance is a high temperature stability in the desired range (e.g. +2 ... +8 °C or +15 ... +25 °C) for 96 hours at +30 °C or ± 0 °C ambient temperatures. A 96 hour validation for summer and winter shipments is available using the standard configuration. | ![]() |
Special features
- One EURO-pallet inside universal passive transport container
- Referenced in the IATA Perishable Cargo Regulations manual 2010
- One pack-out configuration for all seasons
- Standard 96 hours and even longer transportation validation possible
- Self-recovering effects and delayed reaction to temperature shocks
- Rental option available (via va-Q-tec Ltd. / U.K)
Product data
| Article No.: | BC000001 |
| Outside dimension (max.) | 1423 mm x 1093 mm x 1580 mm (h) / 56.0" x 43.0" x 62.2" |
| External volume | 2.46 m³ / 86.6 cubic ft |
| Inside dimension (max.) | 1200 mm x 850 mm 1220 mm (h) / 47.2" x 33.5" x 48.0" |
| Internal volume (max. payload) | 1.24 m³ / 43.9 cubic ft |
| Volumetric weight | 415 kg |
| Tare weight | 320 kg / 706 lbs |
| Total weight | 440 kg / 970 lbs (with standard features for 2 °C to 8 °C) |
| Maximum payload | 500 kg |
| R-value | 5.00 (m²K)/W |
| U-value | 0.20 W/(m²K) |
| Q-value | 1.95 W/K |
| Standard features | • 36 pcs va-Q-accu with temperature display • Top rack for 2 layers accus • 2 door baskets • Document holder |
| Options & Accessories | • 2 Back accu holders • Floor grid • Data logger display for inside and outside temperature • Check system: va-Q-check(for rental only) or RFID Antenna (for Yes / No function test) • Accu conditioning rack (Max. 40 pcs accus) |
Application example
va-Q-tainer EU (summer scenario)
- Outside temperature: +30 °C
- Inside temperature: +2 °C ... +8 °C
- Contents: 36 pcs va-Q-accus 27L+04G, 100 kg goods
- va-Q-tainer wasn't pre-cooled

va-Q-tainer EU (winter scenario)
- Outside temperature: ±0 °C
- Inside temperature: +2 °C ... +8 °C
- Contents: 36 pcs va-Q-accus 27L+04G, 100 kg goods
- va-Q-tainer wasn't pre-cooled