• Deutsch (de)
  • Englisch (en)

va-Q-tainer EURO

General information

The va-Q-tainer EURO has loading area for one EURO pallet inside (120 cm x 80 cm). The va-Q-tainer is extraordinarily suitable for the transportation of temperature sensitive goods, in particular pharmaceutical and biotechnological goods.

The typical performance is a high temperature stability in the desired range (e.g. +2 ... +8 °C or +15 ... +25 °C) for 96 hours at +30 °C or ± 0 °C ambient temperatures. A 96 hour validation for summer and winter shipments is available using the standard configuration.

Special features

  • One EURO-pallet inside universal passive transport container
  • Referenced in the IATA Perishable Cargo Regulations manual 2010
  • One pack-out configuration for all seasons
  • Standard 96 hours and even longer transportation validation possible
  • Self-recovering effects and delayed reaction to temperature shocks
  • Rental option available (via va-Q-tec Ltd. / U.K)

Product data

Article No.:BC000001
Outside dimension (max.)1423 mm x 1093 mm x 1580 mm (h) / 56.0" x 43.0" x 62.2"
External volume2.46 m³ / 86.6 cubic ft
Inside dimension (max.)1200 mm x 850 mm 1220 mm (h) / 47.2" x 33.5" x 48.0"
Internal volume (max. payload)1.24 m³ / 43.9 cubic ft
Volumetric weight415 kg
Tare weight320 kg / 706 lbs
Total weight440 kg / 970 lbs (with standard features for 2 °C to 8 °C)
Maximum payload500 kg
R-value5.00 (m²K)/W
U-value0.20 W/(m²K)
Q-value1.95 W/K
Standard features• 36 pcs va-Q-accu with temperature display • Top rack for 2 layers accus • 2 door baskets • Document holder
Options & Accessories• 2 Back accu holders • Floor grid • Data logger display for inside and outside temperature • Check system: va-Q-check(for rental only) or RFID Antenna (for Yes / No function test) • Accu conditioning rack (Max. 40 pcs accus)

Application example


va-Q-tainer EU (summer scenario)
  • Outside temperature: +30 °C
  • Inside temperature: +2 °C ... +8 °C
  • Contents: 36 pcs va-Q-accus 27L+04G, 100 kg goods
  • va-Q-tainer wasn't pre-cooled


va-Q-tainer EU (winter scenario)
  • Outside temperature: ±0 °C
  • Inside temperature: +2 °C ... +8 °C
  • Contents: 36 pcs va-Q-accus 27L+04G, 100 kg goods
  • va-Q-tainer wasn't pre-cooled